FEATURES
•Calculates bottom hole static temperature (BHST) or temperature gradient (TG)
•Calculates bottom hole circulating temperature (BHCT)
•Supports US and Metric units
•Utilizes methodologies and data found in API Recommended Practice 10B-2 Second Edition, April 2013

INPUTS
•True Vertical Depth (1000 - 22000 ft and 300 - 6600 m)
•Measured Depth (≥ True Vertical Depth)
•Temperature Gradient (0.7 - 1.9 °F/100 ft and 1.6 - 3.6 °C/100 m)
•Bottom Hole Static Temperature (87 - 498 °F and 32 - 264 °C)

OUTPUTS
•Bottom Hole Static Temperature (°F or °C)
•Bottom Hole Circulating Temperature (°F or °C)
•Temperature Gradient (°F/100 ft or °C/100 m)

METHODOLOGY
The tables in Annex D of API RP 10B-2 are a matrix of predicted circulating temperatures for the following well simulation schedules as a function of true vertical depth and temperature gradient.

•Casing
•Liner
•Squeeze

Temperature predictions are given for true vertical depths ranging from 1,000 ft to 22,000 ft for US units and 300 m to 6,600 m for metric units and temperature gradients ranging from 0.9 to 1.9 for US units and 1.6 to 3.6 for metric units.

To predict bottom hole temperatures, BHT utilizes a standard regression technique. This technique, when used in combination with cited tables in API RP 10B-2 Annex D, allows BHT to predict bottom hole temperatures for any depth-gradient input combination that fall within the bounds of relevant tables.

Smaller temperature gradients than those listed in Annex D have been extrapolated from 0.9 °F/100 ft down to 0.7 °F/100 ft in response to a customer request. Temperature predictions for this gradient range utilize the same regression technique referenced above.

*Note: No extrapolation is performed when using metric units

If the user-defined measured depth value is greater than true vertical depth by 1,000 ft or more or 300 m or more, the well is assumed to be highly deviated, lateral, or horizontal and the predicted bottom hole circulation temperature is set equivalent to the bottom hole static temperature value.

FEEDBACK
As awesome as we think we are, we know we’re not perfect. What you have is our first attempt to address what we perceived the core needs of our target audience to be. As you begin to integrate this app into your work life we expect errors, short-comings and worthwhile enhancements to become apparent.

While we welcome praise, we find constructive (and respectful) criticism to be of more value. Please don’t hesitate to send us thoughts, comments and questions on any of our products or new products you would like to see. founders@threeedev.com

更新履歴
UI Enhancements to make it more user-friendly
  • 現在ランキング圏外です。
更新日時:2024年12月27日 12時39分
 
ブログパーツ第二弾を公開しました!ホームページでアプリの順位・価格・周辺ランキングをご紹介頂けます。
ブログパーツ第2弾!

アプリの周辺ランキングを表示するブログパーツです。価格・順位共に自動で最新情報に更新されるのでアプリの状態チェックにも最適です。
ランキング圏外の場合でも周辺ランキングの代わりに説明文を表示にするので安心です。

サンプルが気に入りましたら、下に表示されたHTMLタグをそのままページに貼り付けることでご利用頂けます。ただし、一般公開されているページでご使用頂かないと表示されませんのでご注意ください。

幅200px版

幅320px版
 
Now Loading...

「iPhone & iPad アプリランキング」は、最新かつ詳細なアプリ情報をご紹介しているサイトです。 お探しのアプリに出会えるように様々な切り口でページをご用意しております。
メニュー」よりぜひアプリ探しにお役立て下さい。

  コンタクト   プライバシーポリシー

Presents by $$308413110    スマホからのアクセスにはQRコードをご活用ください。 →

Now loading...screenshot
スマートフォン用サイトへ >