Adiabatic process is a process in which heat exchange does not take place between a thermodynamic system and its surroundings. Behavior of reversible adiabatic process is described by Poisson's equations. Adiabatic Calculator mini is a software that solves the Poisson's equations. This Adiabatic Calculator mini is a subset of iPad Adiabatic Calculator software. Pressure unit and temperature unit are fixed to [MPa] and Kelvin temperature [K].
It's possible to change one of input data one after another. Thus it's possible to get output data which correspond to the changed input data.
Adiabatic Calculator mini Lite is a Lite version of the Adiabatic Calculator mini software. This can operate the P button up to 2 times. When 10 minutes pass and the software is resumed, the P button can be used again.
(Example)
There is air of 1 atmosphere ( = 0.1[MPa]) and 300[K]. When volume of the air is adiabatically compressed into 1/20, how do the temperature and the pressure change?
When the volume is compressed into 1/25, 1/30, and 1/35, how do they change?
Assume that ratio of specific heats of the air is 1.4
(Answer)
This software calculates output data based on one pair data of initial and final state. Ratio of the pair data is used for the calculation.
In this example, pair data is initial and final volumes
Enter pair data as follows.
V1 = 20[L], Vo12 = 1[L]
Enter other known data as follows.
P1 = 0.1[MPa]
T1 = 300[K].
Enter ratio of specific heats as follows.
k = 1.4
To execute calculation, P button of the pair data is touched out. There are initial side and final side P buttons for the pair data. Which side button to select depends on calculation mode.
In this example, we want to get P2 and T2 data that correspond to changed V1 data. Output data is opposite side to the input data. In this case, set calculation mode to Fowd mode.
Touch out V1_P button.
We obtain 6.63[MPa] and 994.3[K] as the final pressure and the final temperature , respectively.
Next enter increment data as follows.
Delta = 5[L]
Touch out + button.
For the volume compression into 1/25, we obtain 9.1[MPa] and 1087[K] as the final pressure and the final temperature.
Next touch out + button. We can obtain the next output data.
By use of + or - button, it's possible to change one of input data one after another and to get output data which corresponds to the changed input data.
更新履歴
This app has been updated by Apple to use the latest Apple signing certificate.
Updated for iOS10 and the new SDK of Xcode8.
It's possible to change one of input data one after another. Thus it's possible to get output data which correspond to the changed input data.
Adiabatic Calculator mini Lite is a Lite version of the Adiabatic Calculator mini software. This can operate the P button up to 2 times. When 10 minutes pass and the software is resumed, the P button can be used again.
(Example)
There is air of 1 atmosphere ( = 0.1[MPa]) and 300[K]. When volume of the air is adiabatically compressed into 1/20, how do the temperature and the pressure change?
When the volume is compressed into 1/25, 1/30, and 1/35, how do they change?
Assume that ratio of specific heats of the air is 1.4
(Answer)
This software calculates output data based on one pair data of initial and final state. Ratio of the pair data is used for the calculation.
In this example, pair data is initial and final volumes
Enter pair data as follows.
V1 = 20[L], Vo12 = 1[L]
Enter other known data as follows.
P1 = 0.1[MPa]
T1 = 300[K].
Enter ratio of specific heats as follows.
k = 1.4
To execute calculation, P button of the pair data is touched out. There are initial side and final side P buttons for the pair data. Which side button to select depends on calculation mode.
In this example, we want to get P2 and T2 data that correspond to changed V1 data. Output data is opposite side to the input data. In this case, set calculation mode to Fowd mode.
Touch out V1_P button.
We obtain 6.63[MPa] and 994.3[K] as the final pressure and the final temperature , respectively.
Next enter increment data as follows.
Delta = 5[L]
Touch out + button.
For the volume compression into 1/25, we obtain 9.1[MPa] and 1087[K] as the final pressure and the final temperature.
Next touch out + button. We can obtain the next output data.
By use of + or - button, it's possible to change one of input data one after another and to get output data which corresponds to the changed input data.
更新履歴
This app has been updated by Apple to use the latest Apple signing certificate.
Updated for iOS10 and the new SDK of Xcode8.
ブログパーツ第二弾を公開しました!ホームページでアプリの順位・価格・周辺ランキングをご紹介頂けます。
ブログパーツ第2弾!
アプリの周辺ランキングを表示するブログパーツです。価格・順位共に自動で最新情報に更新されるのでアプリの状態チェックにも最適です。
ランキング圏外の場合でも周辺ランキングの代わりに説明文を表示にするので安心です。
サンプルが気に入りましたら、下に表示されたHTMLタグをそのままページに貼り付けることでご利用頂けます。ただし、一般公開されているページでご使用頂かないと表示されませんのでご注意ください。
幅200px版
幅320px版
Now Loading...
「iPhone & iPad アプリランキング」は、最新かつ詳細なアプリ情報をご紹介しているサイトです。
お探しのアプリに出会えるように様々な切り口でページをご用意しております。
「メニュー」よりぜひアプリ探しにお役立て下さい。
Presents by $$308413110 スマホからのアクセスにはQRコードをご活用ください。 →
Now loading...