MUVerify Lite is the free Cobalt-only version of MUVerify.
The Lite version comes with a sample Cobalt Machine that can be edited in order to reflect the actual data of the user Cobalt machine.
This version does not allow neither create nor import new machines, and does not support LINACs.

MUVerify Lite provides an independent second check of the calculated monitor units or time in static non IMRT X-ray radiotherapy treatment fields. Using the definitions of the AAPM Task Group 114, MUVerify computes “MU verification” (MUV). Several authors and organizations have discussed the need of a second independent check and the present consensus is that MUV remains necessary.

It is important to note that MUVerify Lite computes “MU verification” (MUV), only for the purpose of confirming “primary MU”, and is not intended for the delivery of radiation.

MUVerify Lite implements simple and well known methods for computing monitor units. One of the main goals of MUV is provide independent results, unrelated to main planning systems (TPS). In the pursuit of independence we have included some generic dosimetry information to avoid using the same data of your TPS. The “generic dosimetry data” is based on a library of PDD, NPSF and other parameters representative of typical photon beams. The inclusion of a generic dosimetry library frees the user from entering extensive tables, which is cumbersome for a mobile app and error prone. The beam quality index for searching and interpolation in the dosimetry library is TPR20/TPR10.

MUVerify Lite can be used only for Cobalt-60 therapy units. All computations are for the central axis. Radiation fields allows the inclusion of physical wedge and trays.
For the case of shaped fields (with cerrobend blocks) the user can enter the effective field size. Regarding heterogeneity corrections only the lung is considered; an optional parameter sets the thickness of lung that the beam is crossing.

MUVerify Lite keeps commissioning as simple as possible. The input of measured data is minimalistic if compared with a full-fledged typical TPS. Input of the required data should not take more than 15 minutes and all the information is part of routine in a radiotherapy department, so no exclusive measurements will be necessary.

The MUV value resulting from MUVerify Lite is compared with the primary MU from the TPS. For most of the fields the agreement should be better than 2%, but for complex fields using a thick physical wedge or in the presence of lungs the deviation could be greater. The adoption of an action level is left to the user, but a recommendation of 5% is widely accepted.

  • 現在ランキング圏外です。
更新日時:2024年7月8日 15時01分
 
ブログパーツ第二弾を公開しました!ホームページでアプリの順位・価格・周辺ランキングをご紹介頂けます。
ブログパーツ第2弾!

アプリの周辺ランキングを表示するブログパーツです。価格・順位共に自動で最新情報に更新されるのでアプリの状態チェックにも最適です。
ランキング圏外の場合でも周辺ランキングの代わりに説明文を表示にするので安心です。

サンプルが気に入りましたら、下に表示されたHTMLタグをそのままページに貼り付けることでご利用頂けます。ただし、一般公開されているページでご使用頂かないと表示されませんのでご注意ください。

幅200px版

幅320px版
 
Now Loading...

「iPhone & iPad アプリランキング」は、最新かつ詳細なアプリ情報をご紹介しているサイトです。 お探しのアプリに出会えるように様々な切り口でページをご用意しております。
メニュー」よりぜひアプリ探しにお役立て下さい。

  コンタクト   プライバシーポリシー

Presents by $$308413110    スマホからのアクセスにはQRコードをご活用ください。 →

Now loading...screenshot
スマートフォン用サイトへ >