Oxyg'App |
価格 | 無料 | ダウンロード |
||
---|---|---|---|---|
ジャンル | 教育 | |||
サイズ | 32.3MB | |||
開発者 | L'Institut universitaire de cardiologie et de pneumologie de Québec (IUCPQ) | |||
順位 |
| |||
リリース日 | 2023-11-10 17:00:00 | 評価 | 評価が取得できませんでした。 | |
互換性 | iOS 13.0以降が必要です。 iPhone、iPad および iPod touch 対応。 |
Oxygen management should rely on oxygenation targets, with minimal and maximal boundaries to avoid both hypoxemia and hyperoxemia. Oxygen titration using targets based on arterial saturation (SaO2) are not feasible due to discontinuous measurements of this parameter that requires an arterial blood gas analysis. The oxygen support must be titrated based on SpO2 that allows continuous measurements of patient oxygenation, even though this technology has limitations and needs improvement. We may hope for a major technological evolution as the main working principles of this technology, which are more than 50 years old, have not changed appreciably. Waiting for this improvement in pulse oximetry technology, clinicians should tread carefully and apply algorithms to correct for these deficiencies. Whatever the clinician thinks is the appropriate oxygenation target, this "optimal SaO2" target needs to be corrected when utilizing the SpO2 for the titration based on skin pigmentation and oximeter brand. It has become increasingly apparent that the SpO2 target cannot simply be the SaO2 target!
To facilitate the quest of the optimal SpO2 targets and to promote a more homogeneous management of patients’ oxygenation regardless of skin pigmentation or monitoring device of oxygenation there are several potential solutions. We believe that one SpO2 target does not fit all patients and that further clinical trials and clinical guidelines should use corrected SpO2 targets rather than universal targets for all patients. Consequently, clinicians should first define a SaO2 target relative to the patient under respiratory support and then apply corrections for the mean bias related to the skin pigmentation and to the oximeter used to get the corrected SpO2.
更新履歴
Adding a warning to emphasize educational intent.
To facilitate the quest of the optimal SpO2 targets and to promote a more homogeneous management of patients’ oxygenation regardless of skin pigmentation or monitoring device of oxygenation there are several potential solutions. We believe that one SpO2 target does not fit all patients and that further clinical trials and clinical guidelines should use corrected SpO2 targets rather than universal targets for all patients. Consequently, clinicians should first define a SaO2 target relative to the patient under respiratory support and then apply corrections for the mean bias related to the skin pigmentation and to the oximeter used to get the corrected SpO2.
更新履歴
Adding a warning to emphasize educational intent.
ブログパーツ第二弾を公開しました!ホームページでアプリの順位・価格・周辺ランキングをご紹介頂けます。
ブログパーツ第2弾!
アプリの周辺ランキングを表示するブログパーツです。価格・順位共に自動で最新情報に更新されるのでアプリの状態チェックにも最適です。
ランキング圏外の場合でも周辺ランキングの代わりに説明文を表示にするので安心です。
サンプルが気に入りましたら、下に表示されたHTMLタグをそのままページに貼り付けることでご利用頂けます。ただし、一般公開されているページでご使用頂かないと表示されませんのでご注意ください。
幅200px版
幅320px版
Now Loading...
「iPhone & iPad アプリランキング」は、最新かつ詳細なアプリ情報をご紹介しているサイトです。
お探しのアプリに出会えるように様々な切り口でページをご用意しております。
「メニュー」よりぜひアプリ探しにお役立て下さい。
Presents by $$308413110 スマホからのアクセスにはQRコードをご活用ください。 →
Now loading...